Product information and disease descriptionPlace of product in therapyApproaches to treatment
Care management intervention strategies
21 evidence topics · 18 sources
Eligibility assessment: baseline testing at the study site
Eligibility assessment: anti-AAV9 antibody testing
Eligibility assessment: three-month biomarker run-in before treatment, as stated in August 2025
Immunomodulation: regimen under the modified protocol
Immunomodulation: changes made during phase 1 to limit steroid myopathy and renal toxicity
Infection prophylaxis regimen during immunomodulation
No evidence found.
Complement monitoring and threshold for a C5 inhibitor
Platelet and terminal complement complex monitoring for 3 months in the first 3 participants at the recalibrated dose
Timing of immune adverse events after AAV gene therapy: meta-analysis across diseases
Cardiac and extracardiac surveillance schedule in the consensus statement
| Test | Frequency during follow-up care |
|---|---|
| Blood tests | “Yearly” |
| 24-hour Holter monitoring | “Every 6 mo if enlarged atria” |
| Cardiac magnetic resonance | “Every 2-3 y” |
| Neurologic evaluation | “Yearly if symptoms, otherwise, every 3-4 y” |
| Development evaluation | “At baseline and if new manifestations appear” |
| Ophthalmologic evaluation | “Every 3-5 y” |
| Genetic counseling | “At diagnosis and when needed” |
Surveillance schedule in GeneReviews
| Evaluation | Frequency |
|---|---|
| Electrocardiography | “At least annually” |
| Echocardiography | “At least every 1-2 yrs, transitioning to every 6 mos once hypertrophy becomes moderate or if hypertrophy is rapidly progressive” |
| Cardiac MRI | “Consider every 1-2 yrs to evaluate progression of fibrosis.” |
| Ambulatory arrhythmia monitoring | “As needed for eval of symptoms consistent w/bypass track (e.g. palpitations, pre-syncope)” |
| Formal developmental assessments | “Every 3-5 yrs during childhood” |
| Ophthalmologic examination | “Every 3-5 yrs or as needed based on concerns about visual acuity, visual field deficits, &/or color vision (as an indicator of cone function)” |